Temperature, CO2, Humidity, and VOC Sensor
With Occupancy Status, Occupancy Override, and Setpoint Adjust
LCD Display, Alarm Indicator, and Fan Speed Control
Carrier’s line of intelligent ZS space sensors provide the function and flexibility you need to manage the conditions important to the comfort, productivity, and sustainability of your building.
The ZS sensors are available in a variety of zone sensing combinations to address your application needs. These combinations include temperature, relative humidity, and indoor air quality (carbon dioxide and volatile organic compounds (VOCs).
Designed to work with i-Vu controllers and the i-Vu Building Automation System, the ZS sensor line includes the ZS Standard, ZS Plus, ZS Pro and ZS Pro-F.
ZS STANDARD ZS PRO ZSP-CAR SENSORS in:
VIRGINIA: Alexandria, Annandale, Arlington, Ashburn, Burke, Centreville, Chantilly, Crystal City, Dale City, Dulles, Fairfax, Falls Church, Fort Belvoir, Great Falls, Herndon, Leesburg, Lincoln, Lorton, Manassas, McLean, Oakton, Purcellville, Reston, Springfield, Stafford, Sterling, Vienna, Woodbridge.
MARYLAND: Annapolis, Aspen Hill, Beltsville, Bethesda, Chevy Chase, College Park, Gaithersburg, Hampstead, Hyattsville, Lanham, Laurel, Montgomery Village, Potomac, Rockville, Silver Spring, Takoma Park, Temple Hills, National Harbor, Cabin John, East Riverdale, Riverdale, Landover, Cheverly, Oxon Hill, Fort Washington, Indian head, Morningside.
WASHINGTON, DC
HVAC – Heating – Air Conditioning Repair Experts at Perryaire.
ZS PRO ZSP-CAR SENSOR
ZS Standard |
ZS Plus |
ZS Pro |
ZS Pro-F |
|
---|---|---|---|---|
Model Number | ZS-CAR | ZSPL-CAR | ZSP-CAR | ZSPF-CAR |
Temp, CO2, Humidity, and VOC Options | Yes | Yes | Yes | Yes |
Neutral color | Yes | Yes | Yes | Yes |
Addressable / supports daisy-chaining | Yes | Yes | Yes | Yes |
Hidden communication port | Yes | Yes | Yes | Yes |
Mounts on a standard 2” by 4” electrical box | Yes | Yes | Yes | Yes |
Occupancy status indicator | Yes | Yes | Yes | |
Push-button occupancy override | Yes | Yes | Yes | |
Setpoint adjust | Yes | Yes | Yes | |
Large, easy- to-read LCD | Yes | Yes | ||
Alarm indicator | Yes | Yes | ||
Fan speed control | Yes | |||
Cooling / Heating / Fan Only – Mode Control | Yes | |||
°F to °C conversion button | Yes |
Sensing Element | Range | Accuracy |
---|---|---|
Temperature with any Option (excluding Humidity) | -4° to 122° F (-20° C to 50° C) | ±0.35° F (0.2° C) |
Temperature with Humidity and any Option | 50° F to 104° F (10° C to 40° C) | ±0.5° F (0.3° C) |
Humidity | 10% to 90% | ±1.8% typical |
CO2 | 400 to 1250 PPM | ±30PPM or +/-3% of reading (greater of two) |
CO2 | 1250 to 2000 PPM | ±5% of reading plus 30 PPM |
VOC | 0 to 2,000 PPM | ±100 PPM |
Power Requirements | Sensor Type | Power Required |
---|---|---|
Temperature Only Temperature with Humidity |
All Models | 12 Vdc @ 8 mA |
Temp with VOC, or Temp/VOC/Humidity | All Models | 12 Vdc @ 60 mA |
Temp with CO2 , or Temp/ CO2/Humidity | All Models | 12 Vdc @ 15 mA (idle) to 190 mA (CO2 measurement cycle) |
Power Supply | A controller supplies the Rnet sensor network with 12 Vdc @ 210 mA. Additional power may be required for your application. See sensor power requirements above. | ||||||||||
Communication | 115 kbps Rnet connection between sensor(s) and controller 15 sensors max per Rnet network; 5 sensors max per control program
|