We offer the most competitive prices for HVAC Heating Cooling Air Conditioning products and installation in Arlington – Alexandria – Northern Virginia – Washington DC and Maryland Air Terminals 35J
Call Perry Aire today 703-521-2226!
45 to 3,700 Nominal Cfm
The 35J round tube, single-duct unit provides cooling only to meet retrofit and special application needs. Terminal units are designed to allow maximum flexibility in configuration and control. The small size of the unit ensures an easy fit in all applications.
Offering AXIS™ 35J SINGLE-DUCT RETROFIT TERMINALS in:
VIRGINIA: Alexandria, Annandale, Arlington, Ashburn, Burke, Centreville, Chantilly, Crystal City, Dale City, Dulles, Fairfax, Falls Church, Fort Belvoir, Great Falls, Herndon, Leesburg, Lincoln, Lorton, Manassas, McLean, Oakton, Purcellville, Reston, Springfield, Stafford, Sterling, Vienna, Woodbridge.
MARYLAND: Annapolis, Aspen Hill, Beltsville, Bethesda, Chevy Chase, College Park, Gaithersburg, Hampstead, Hyattsville, Lanham, Laurel, Montgomery Village, Potomac, Rockville, Silver Spring, Takoma Park, Temple Hills, National Harbor, Cabin John, East Riverdale, Riverdale, Landover, Cheverly, Oxon Hill, Fort Washington, Indian head, Morningside.
WASHINGTON, DC
HVAC – Heating – Air Conditioning Repair Experts at Perryaire.
AXIS™ 35J SINGLE-DUCT RETROFIT TERMINAL
Performance Features
- Airflow capacities from 45 to 3700 cfm
- Round inlet sizes from 4 in. through 16 in. diameter
- Rectangular inlet on size 22
- 22 gauge, galvanized steel casing construction
- Converts high-pressure mechanical constant volume systems to low-pressure variable volume systems
- Linear, multiple-point, averaging velocity sensor with an amplified signal
- Damper blade has a flexible gasket for tight airflow shutoff
- Damper blade operates over a full 90°
- All damper assemblies utilize a solid ½ in. shaft that rotates in self-lubricating Delrin® bearings
- Pressure independent or dependent controls, including Carrier i-Vu Open (BACnet), Carrier Comfort Network® (CCN), analog, or pneumatic controls
Reliability Features
- Casings meet UL-181 and NFPA-90A requirements
Maintenance Features
- NEMA 2 steel control enclosure for electric or electronic components
- Label information adhered to each unit includes model, size, airflow (cfm), balancing chart, and tagging data
Installation Features
- Factory-installed controls
- All round collars accommodate standard spiral and flex duct sizes
- Balancing taps provided for easy airflow verification
Standard Warranty
- One-year parts
Factory-Installed Options
- Control options:
- Analog electronic controls
- Carrier i-Vu Open VAV or VVT controls
- Carrier Comfort Network (CCN) VAV or VVT controls
- Pneumatic controls
- No controls or field-supplied DDC (direct digital controls) third party controls for factory mounting
- Left-hand or right-hand control enclosure
- 20 gauge, galvanized steel casing
- 304 stainless steel casing
Field-Installed Accessories
- Remote wall sensor
- Supply-air temperature sensor